From 23989f4a18b679e4bef2cce7cbfe747816087cdb Mon Sep 17 00:00:00 2001 From: shen <> Date: Sun, 8 Nov 2026 05:32:04 -0800 Subject: [PATCH] feat(battery): implement emergency safe shutdown when battery <= 5% discharging - Add should_shutdown() check in BatteryPolicy and trigger_shutdown() in phone-battery-guard.py. - Auto sync filesystems and invoke safe poweroff if SoC drops to 5% while on battery/discharging. - Do not power off if external charger is actively connected and charging. - Update openrc service command args with --shutdown-at 5. - Add unit tests for emergency shutdown, discharging detection, and threshold validation. --- scripts/phone-battery-guard.openrc | 4 +- scripts/phone-battery-guard.py | 72 +++++++++++++++++++++++++++--- tests/test_battery_guard.py | 50 +++++++++++++++++++++ 3 files changed, 119 insertions(+), 7 deletions(-) diff --git a/scripts/phone-battery-guard.openrc b/scripts/phone-battery-guard.openrc index e0659ef..287bb4f 100755 --- a/scripts/phone-battery-guard.openrc +++ b/scripts/phone-battery-guard.openrc @@ -1,8 +1,8 @@ #!/sbin/openrc-run -description="Platina battery health and anti-swelling daemon (maintains 50-65% SoC)" +description="Platina battery health and emergency shutdown daemon (50-65% SoC, auto-poweroff <= 5%)" command="/usr/local/sbin/platina-battery-guard" command_user="root:root" -command_args="--low ${low:-50} --high ${high:-65} --max-temp ${max_temp:-45} --interval ${interval:-60}" +command_args="--low ${low:-50} --high ${high:-65} --max-temp ${max_temp:-45} --shutdown-at ${shutdown_at:-5} --interval ${interval:-60}" command_background="yes" pidfile="/run/platina-battery-guard.pid" output_log="/var/log/platina-battery-guard.log" diff --git a/scripts/phone-battery-guard.py b/scripts/phone-battery-guard.py index 0bdb006..d5b70ed 100755 --- a/scripts/phone-battery-guard.py +++ b/scripts/phone-battery-guard.py @@ -1,12 +1,16 @@ #!/usr/bin/env python3 -"""Battery health daemon: maintains battery state of charge (SoC) between 50% and 65% +"""Battery health and emergency protection daemon: -Prevents battery swelling, chemical degradation and overcharge heat during 24/7 server operation. +1. Maintains battery state of charge (SoC) between 50% and 65% when plugged in. +2. Cuts off charging if battery temperature exceeds max_temp (default 45°C). +3. Automatically triggers safe filesystem sync and shutdown if battery <= 5% while discharging. """ import argparse import os from pathlib import Path +import shutil import signal +import subprocess import sys import time @@ -28,12 +32,15 @@ def find_supply(paths): class BatteryPolicy: - def __init__(self, low=50, high=65, max_temp=45): + def __init__(self, low=50, high=65, max_temp=45, shutdown_at=5): if not 10 <= low < high <= 95: raise ValueError('Invalid battery thresholds (expected 10 <= low < high <= 95)') + if not 1 <= shutdown_at < low: + raise ValueError('Invalid shutdown threshold (expected 1 <= shutdown_at < low)') self.low = low self.high = high self.max_temp = max_temp + self.shutdown_at = shutdown_at self.charging_state = True self.thermal_throttled = False @@ -64,6 +71,12 @@ class BatteryPolicy: return True return self.charging_state + def should_shutdown(self, capacity, is_discharging=True): + """Returns True if battery is critically low and actively discharging.""" + if capacity is None: + return False + return bool(is_discharging and capacity <= self.shutdown_at) + def get_temp(battery_dir): if not battery_dir: @@ -89,6 +102,46 @@ def get_capacity(battery_dir): return None +def is_battery_discharging(battery_dir, charger_dir=None): + """Determine whether the battery is currently discharging / running without external power.""" + if battery_dir: + status_file = battery_dir / 'status' + if status_file.exists(): + try: + status = status_file.read_text().strip().lower() + if status == 'discharging': + return True + if status in ('charging', 'full'): + return False + except OSError: + pass + if charger_dir: + online_file = charger_dir / 'online' + if online_file.exists(): + try: + return online_file.read_text().strip() == '0' + except OSError: + pass + return False + + +def trigger_shutdown(executor=subprocess.run): + """Sync filesystem and execute safe poweroff.""" + print('platina-battery-guard: CRITICAL: battery <= 5% and discharging; emergency poweroff to protect filesystem', flush=True) + try: + os.sync() + except Exception: + pass + bin_candidates = [ + shutil.which('platina-poweroff'), + '/usr/local/sbin/platina-poweroff', + shutil.which('poweroff'), + '/usr/sbin/poweroff', + ] + target_bin = next((b for b in bin_candidates if b and (Path(b).exists() or shutil.which(b))), '/usr/sbin/poweroff') + return executor([target_bin], check=True) + + def set_charging(battery_dir, charger_dir, enable): applied = False val = '1' if enable else '0' @@ -139,12 +192,13 @@ def main(): parser = argparse.ArgumentParser(description=__doc__) parser.add_argument('--low', type=int, default=50, help='Lower SoC percentage to resume charging (default: 50)') parser.add_argument('--high', type=int, default=65, help='Upper SoC percentage to stop charging (default: 65)') + parser.add_argument('--shutdown-at', type=int, default=5, help='Emergency shutdown SoC percentage when discharging (default: 5)') parser.add_argument('--max-temp', type=int, default=45, help='Thermal cutoff threshold in Celsius (default: 45)') parser.add_argument('--interval', type=float, default=60, help='Poll interval in seconds (default: 60)') parser.add_argument('--once', action='store_true', help='Evaluate once and exit') args = parser.parse_args() - policy = BatteryPolicy(args.low, args.high, max_temp=args.max_temp) + policy = BatteryPolicy(args.low, args.high, max_temp=args.max_temp, shutdown_at=args.shutdown_at) battery_dir = find_supply(BATTERY_PATHS) charger_dir = find_supply(CHARGER_PATHS) @@ -160,7 +214,14 @@ def main(): while not stop_event: capacity = get_capacity(battery_dir) temp = get_temp(battery_dir) + discharging = is_battery_discharging(battery_dir, charger_dir) + if capacity is not None: + # Emergency low-battery safety shutdown: prevent brownout filesystem corruption + if policy.should_shutdown(capacity, is_discharging=discharging): + trigger_shutdown() + break + action = policy.evaluate(capacity, temp=temp) set_charging(battery_dir, charger_dir, action) if policy.thermal_throttled: @@ -168,7 +229,8 @@ def main(): else: status_str = 'Charging enabled' if action else 'Charging paused (protective threshold reached)' temp_str = f', temp={temp/10:.1f}°C' if temp is not None and temp > 150 else (f', temp={temp}°C' if temp is not None else '') - print(f'platina-battery-guard: capacity={capacity}%{temp_str}, threshold=[{args.low}%-{args.high}%], state={status_str}', flush=True) + power_mode = 'discharging' if discharging else 'external-power' + print(f'platina-battery-guard: capacity={capacity}%{temp_str}, power={power_mode}, threshold=[{args.low}%-{args.high}%], state={status_str}', flush=True) if args.once or stop_event: break diff --git a/tests/test_battery_guard.py b/tests/test_battery_guard.py index de4051b..ad5c0ba 100644 --- a/tests/test_battery_guard.py +++ b/tests/test_battery_guard.py @@ -71,6 +71,56 @@ class BatteryGuardTests(unittest.TestCase): self.assertTrue(policy.evaluate(45, temp=410)) self.assertFalse(policy.thermal_throttled) + def test_emergency_low_battery_shutdown(self): + policy = guard.BatteryPolicy(low=50, high=65, shutdown_at=5) + # Above shutdown threshold: no shutdown + self.assertFalse(policy.should_shutdown(10, is_discharging=True)) + self.assertFalse(policy.should_shutdown(6, is_discharging=True)) + # At or below threshold (<= 5) while discharging: should shutdown + self.assertTrue(policy.should_shutdown(5, is_discharging=True)) + self.assertTrue(policy.should_shutdown(3, is_discharging=True)) + self.assertTrue(policy.should_shutdown(1, is_discharging=True)) + # At or below threshold BUT charging / on external power: do NOT shutdown + self.assertFalse(policy.should_shutdown(4, is_discharging=False)) + self.assertFalse(policy.should_shutdown(None, is_discharging=True)) + + def test_invalid_shutdown_thresholds_rejected(self): + with self.assertRaises(ValueError): + guard.BatteryPolicy(low=50, high=65, shutdown_at=0) + with self.assertRaises(ValueError): + guard.BatteryPolicy(low=50, high=65, shutdown_at=50) + + def test_is_battery_discharging_sysfs(self): + with tempfile.TemporaryDirectory() as temp: + battery = Path(temp) / 'battery' + charger = Path(temp) / 'charger' + battery.mkdir() + charger.mkdir() + + (battery / 'status').write_text('Discharging\n') + self.assertTrue(guard.is_battery_discharging(battery, charger)) + + (battery / 'status').write_text('Charging\n') + self.assertFalse(guard.is_battery_discharging(battery, charger)) + + (battery / 'status').unlink() + (charger / 'online').write_text('0\n') + self.assertTrue(guard.is_battery_discharging(battery, charger)) + + (charger / 'online').write_text('1\n') + self.assertFalse(guard.is_battery_discharging(battery, charger)) + + def test_trigger_shutdown_executor(self): + called = [] + + def mock_executor(cmd, **kwargs): + called.append(cmd) + return None + + guard.trigger_shutdown(executor=mock_executor) + self.assertEqual(len(called), 1) + self.assertTrue(any('poweroff' in part for part in called[0])) + if __name__ == '__main__': unittest.main()