feat(battery): implement emergency safe shutdown when battery <= 5% discharging
Offline project checks / check (push) Canceled after 0s
Offline project checks / check (push) Canceled after 0s
- Add should_shutdown() check in BatteryPolicy and trigger_shutdown() in phone-battery-guard.py. - Auto sync filesystems and invoke safe poweroff if SoC drops to 5% while on battery/discharging. - Do not power off if external charger is actively connected and charging. - Update openrc service command args with --shutdown-at 5. - Add unit tests for emergency shutdown, discharging detection, and threshold validation.
This commit is contained in:
@@ -1,8 +1,8 @@
|
||||
#!/sbin/openrc-run
|
||||
description="Platina battery health and anti-swelling daemon (maintains 50-65% SoC)"
|
||||
description="Platina battery health and emergency shutdown daemon (50-65% SoC, auto-poweroff <= 5%)"
|
||||
command="/usr/local/sbin/platina-battery-guard"
|
||||
command_user="root:root"
|
||||
command_args="--low ${low:-50} --high ${high:-65} --max-temp ${max_temp:-45} --interval ${interval:-60}"
|
||||
command_args="--low ${low:-50} --high ${high:-65} --max-temp ${max_temp:-45} --shutdown-at ${shutdown_at:-5} --interval ${interval:-60}"
|
||||
command_background="yes"
|
||||
pidfile="/run/platina-battery-guard.pid"
|
||||
output_log="/var/log/platina-battery-guard.log"
|
||||
|
||||
@@ -1,12 +1,16 @@
|
||||
#!/usr/bin/env python3
|
||||
"""Battery health daemon: maintains battery state of charge (SoC) between 50% and 65%
|
||||
"""Battery health and emergency protection daemon:
|
||||
|
||||
Prevents battery swelling, chemical degradation and overcharge heat during 24/7 server operation.
|
||||
1. Maintains battery state of charge (SoC) between 50% and 65% when plugged in.
|
||||
2. Cuts off charging if battery temperature exceeds max_temp (default 45°C).
|
||||
3. Automatically triggers safe filesystem sync and shutdown if battery <= 5% while discharging.
|
||||
"""
|
||||
import argparse
|
||||
import os
|
||||
from pathlib import Path
|
||||
import shutil
|
||||
import signal
|
||||
import subprocess
|
||||
import sys
|
||||
import time
|
||||
|
||||
@@ -28,12 +32,15 @@ def find_supply(paths):
|
||||
|
||||
|
||||
class BatteryPolicy:
|
||||
def __init__(self, low=50, high=65, max_temp=45):
|
||||
def __init__(self, low=50, high=65, max_temp=45, shutdown_at=5):
|
||||
if not 10 <= low < high <= 95:
|
||||
raise ValueError('Invalid battery thresholds (expected 10 <= low < high <= 95)')
|
||||
if not 1 <= shutdown_at < low:
|
||||
raise ValueError('Invalid shutdown threshold (expected 1 <= shutdown_at < low)')
|
||||
self.low = low
|
||||
self.high = high
|
||||
self.max_temp = max_temp
|
||||
self.shutdown_at = shutdown_at
|
||||
self.charging_state = True
|
||||
self.thermal_throttled = False
|
||||
|
||||
@@ -64,6 +71,12 @@ class BatteryPolicy:
|
||||
return True
|
||||
return self.charging_state
|
||||
|
||||
def should_shutdown(self, capacity, is_discharging=True):
|
||||
"""Returns True if battery is critically low and actively discharging."""
|
||||
if capacity is None:
|
||||
return False
|
||||
return bool(is_discharging and capacity <= self.shutdown_at)
|
||||
|
||||
|
||||
def get_temp(battery_dir):
|
||||
if not battery_dir:
|
||||
@@ -89,6 +102,46 @@ def get_capacity(battery_dir):
|
||||
return None
|
||||
|
||||
|
||||
def is_battery_discharging(battery_dir, charger_dir=None):
|
||||
"""Determine whether the battery is currently discharging / running without external power."""
|
||||
if battery_dir:
|
||||
status_file = battery_dir / 'status'
|
||||
if status_file.exists():
|
||||
try:
|
||||
status = status_file.read_text().strip().lower()
|
||||
if status == 'discharging':
|
||||
return True
|
||||
if status in ('charging', 'full'):
|
||||
return False
|
||||
except OSError:
|
||||
pass
|
||||
if charger_dir:
|
||||
online_file = charger_dir / 'online'
|
||||
if online_file.exists():
|
||||
try:
|
||||
return online_file.read_text().strip() == '0'
|
||||
except OSError:
|
||||
pass
|
||||
return False
|
||||
|
||||
|
||||
def trigger_shutdown(executor=subprocess.run):
|
||||
"""Sync filesystem and execute safe poweroff."""
|
||||
print('platina-battery-guard: CRITICAL: battery <= 5% and discharging; emergency poweroff to protect filesystem', flush=True)
|
||||
try:
|
||||
os.sync()
|
||||
except Exception:
|
||||
pass
|
||||
bin_candidates = [
|
||||
shutil.which('platina-poweroff'),
|
||||
'/usr/local/sbin/platina-poweroff',
|
||||
shutil.which('poweroff'),
|
||||
'/usr/sbin/poweroff',
|
||||
]
|
||||
target_bin = next((b for b in bin_candidates if b and (Path(b).exists() or shutil.which(b))), '/usr/sbin/poweroff')
|
||||
return executor([target_bin], check=True)
|
||||
|
||||
|
||||
def set_charging(battery_dir, charger_dir, enable):
|
||||
applied = False
|
||||
val = '1' if enable else '0'
|
||||
@@ -139,12 +192,13 @@ def main():
|
||||
parser = argparse.ArgumentParser(description=__doc__)
|
||||
parser.add_argument('--low', type=int, default=50, help='Lower SoC percentage to resume charging (default: 50)')
|
||||
parser.add_argument('--high', type=int, default=65, help='Upper SoC percentage to stop charging (default: 65)')
|
||||
parser.add_argument('--shutdown-at', type=int, default=5, help='Emergency shutdown SoC percentage when discharging (default: 5)')
|
||||
parser.add_argument('--max-temp', type=int, default=45, help='Thermal cutoff threshold in Celsius (default: 45)')
|
||||
parser.add_argument('--interval', type=float, default=60, help='Poll interval in seconds (default: 60)')
|
||||
parser.add_argument('--once', action='store_true', help='Evaluate once and exit')
|
||||
args = parser.parse_args()
|
||||
|
||||
policy = BatteryPolicy(args.low, args.high, max_temp=args.max_temp)
|
||||
policy = BatteryPolicy(args.low, args.high, max_temp=args.max_temp, shutdown_at=args.shutdown_at)
|
||||
battery_dir = find_supply(BATTERY_PATHS)
|
||||
charger_dir = find_supply(CHARGER_PATHS)
|
||||
|
||||
@@ -160,7 +214,14 @@ def main():
|
||||
while not stop_event:
|
||||
capacity = get_capacity(battery_dir)
|
||||
temp = get_temp(battery_dir)
|
||||
discharging = is_battery_discharging(battery_dir, charger_dir)
|
||||
|
||||
if capacity is not None:
|
||||
# Emergency low-battery safety shutdown: prevent brownout filesystem corruption
|
||||
if policy.should_shutdown(capacity, is_discharging=discharging):
|
||||
trigger_shutdown()
|
||||
break
|
||||
|
||||
action = policy.evaluate(capacity, temp=temp)
|
||||
set_charging(battery_dir, charger_dir, action)
|
||||
if policy.thermal_throttled:
|
||||
@@ -168,7 +229,8 @@ def main():
|
||||
else:
|
||||
status_str = 'Charging enabled' if action else 'Charging paused (protective threshold reached)'
|
||||
temp_str = f', temp={temp/10:.1f}°C' if temp is not None and temp > 150 else (f', temp={temp}°C' if temp is not None else '')
|
||||
print(f'platina-battery-guard: capacity={capacity}%{temp_str}, threshold=[{args.low}%-{args.high}%], state={status_str}', flush=True)
|
||||
power_mode = 'discharging' if discharging else 'external-power'
|
||||
print(f'platina-battery-guard: capacity={capacity}%{temp_str}, power={power_mode}, threshold=[{args.low}%-{args.high}%], state={status_str}', flush=True)
|
||||
|
||||
if args.once or stop_event:
|
||||
break
|
||||
|
||||
@@ -71,6 +71,56 @@ class BatteryGuardTests(unittest.TestCase):
|
||||
self.assertTrue(policy.evaluate(45, temp=410))
|
||||
self.assertFalse(policy.thermal_throttled)
|
||||
|
||||
def test_emergency_low_battery_shutdown(self):
|
||||
policy = guard.BatteryPolicy(low=50, high=65, shutdown_at=5)
|
||||
# Above shutdown threshold: no shutdown
|
||||
self.assertFalse(policy.should_shutdown(10, is_discharging=True))
|
||||
self.assertFalse(policy.should_shutdown(6, is_discharging=True))
|
||||
# At or below threshold (<= 5) while discharging: should shutdown
|
||||
self.assertTrue(policy.should_shutdown(5, is_discharging=True))
|
||||
self.assertTrue(policy.should_shutdown(3, is_discharging=True))
|
||||
self.assertTrue(policy.should_shutdown(1, is_discharging=True))
|
||||
# At or below threshold BUT charging / on external power: do NOT shutdown
|
||||
self.assertFalse(policy.should_shutdown(4, is_discharging=False))
|
||||
self.assertFalse(policy.should_shutdown(None, is_discharging=True))
|
||||
|
||||
def test_invalid_shutdown_thresholds_rejected(self):
|
||||
with self.assertRaises(ValueError):
|
||||
guard.BatteryPolicy(low=50, high=65, shutdown_at=0)
|
||||
with self.assertRaises(ValueError):
|
||||
guard.BatteryPolicy(low=50, high=65, shutdown_at=50)
|
||||
|
||||
def test_is_battery_discharging_sysfs(self):
|
||||
with tempfile.TemporaryDirectory() as temp:
|
||||
battery = Path(temp) / 'battery'
|
||||
charger = Path(temp) / 'charger'
|
||||
battery.mkdir()
|
||||
charger.mkdir()
|
||||
|
||||
(battery / 'status').write_text('Discharging\n')
|
||||
self.assertTrue(guard.is_battery_discharging(battery, charger))
|
||||
|
||||
(battery / 'status').write_text('Charging\n')
|
||||
self.assertFalse(guard.is_battery_discharging(battery, charger))
|
||||
|
||||
(battery / 'status').unlink()
|
||||
(charger / 'online').write_text('0\n')
|
||||
self.assertTrue(guard.is_battery_discharging(battery, charger))
|
||||
|
||||
(charger / 'online').write_text('1\n')
|
||||
self.assertFalse(guard.is_battery_discharging(battery, charger))
|
||||
|
||||
def test_trigger_shutdown_executor(self):
|
||||
called = []
|
||||
|
||||
def mock_executor(cmd, **kwargs):
|
||||
called.append(cmd)
|
||||
return None
|
||||
|
||||
guard.trigger_shutdown(executor=mock_executor)
|
||||
self.assertEqual(len(called), 1)
|
||||
self.assertTrue(any('poweroff' in part for part in called[0]))
|
||||
|
||||
|
||||
if __name__ == '__main__':
|
||||
unittest.main()
|
||||
|
||||
Reference in New Issue
Block a user